Objective

RTC Registers

CCR ( Clock Control Register )
CCR
31:5 4 3:2 1 0
- CCALEN - CTCRST CLKEN

Bit 0 – CLKEN : Clock Enable

Bit 1 - CTCRST : CTC Reset

Bit 3:2

Bit 4 - CCALEN

Bit 31:5

Time Counter Register
Time Counter Register
Name Description Minimum Value Maximum Value
SEC Seconds value 0 59
MIN Minutes value 0 59
HOUR Hours value 0 23
DOM Day of Month value 1 28,29,30 or 31
( depending on the

month and whether it is a leap year).

DOW Day of Week value 0 6
DOY Day of Year value 1 365 (366 for Leap Year)
MONTH Month value 1 12
YEAR Year value 0 4095
Consolidated Time Registers

The values of the Time Counters can optionally be read in a consolidated format which allows the programmer to read all time counters with only three read operations.

The minimum and maximum values of the fields are same as respective Time Counter Register.


Consolidated Time Register 0 (CTIME0)

CTIME0
31:27 26:24 23:21 20:16 15:14 13:8 7:6 5:0
Reserved Day of Week Reserved Hours Reserved Minute Reserved Second

Consolidated Time Register 1 (CTIME1)

CTIME1
31:27 27:16 15:12 11:8 7:5 4:0
Reserved Year Reserved Month Reserved Day of Month


Consolidated Time Register 2 (CTIME2)

CTIME2
31:12 11:0
Reserved Day of Year