In this tutorial, we are going to discuss the Timer module of 8051.
First, we will see what are timers, their working and later we will configure the 8051 timers to generate the delay of 100ms and 500ms respectively. At the end, we will see how to use the ExploreEmdedded Timer library.

8051 Timer Module

8051 has two indepenndent timer which can be used as timer(to generate delays)/Counters(count external events).
Timer 1 is also used for generating baud rate in serial communication, which we will discuss in the next tutorial
Below table provides the details of the 8051 Timers.

Timer Size Control Register Count Register Min Delay Max Delay
TIMER0 16-bit TMOD,TCON TH0,TL0 1.085µs 71.107ms
TIMER1 16-bit TMOD,TCON TH1,TL1 1.085µs 71.107ms
TIMER2(8052 only) 16-bit T2CON RCAP2H,RCAP2L 1.085µs 71.107ms

Timer Basics

As the name suggests these are used to measure the time or generate the accurate time delay. The microcontroller can also generate/measure the required time delays by running loops, but the timer/counter relieves the CPU from that redundant and repetitive task, allowing it to allocate maximum processing time for other tasks.

The timer is nothing but a simple binary counter that can be configured to count clock pulses(Internal/External). Once it reaches the Max value, it will roll back to zero setting up an OverFlow flag and generates the interrupt if enabled.

Timer.gif


fig 1:Basic Timer

The Timer 0 is 16 bit wide as shown. This can be accessed as 2 eight bit registers TL0 and TL1. Same applies to Timer 1. The 8051 timer and counter are the same units, but in this tutorial, we will discuss only the timer unit to simplify the discussion. Fig 1, shows the basic 8051 timer unit. The registers TCON and TMOD affect the timer operation. The clock frequency is divided by 12 and used by the timer unit. Thus if a 11.0592MHz external crystal is used, the timer uses a frequency of 921KHz. Thus timer increments every (1/921Khz) = 1.085μ seconds.

  • The C/Ṫ = 0 bit of TMOD register selects operation of Timer/counter unit as timer.
  • The TR bit of TCON register is used to start the timer.




Timer Registers

TMOD
Timer1 Timer 0
7 6 5 4 3 2 1 0
Gate C/T M1 M0 Gate C/T M1 M0
  • Gate Control

0 = Timer enabled
1 = Timer enabled if INTx is high

  • C/T:Counter or Timer Selector

0 = Internal count source (clock/12)
1 = External count source T0/T1(P3.4/P3.5) pin.

  • M1-M0:Mode Control

00-Mode 0, 13 bit count mode
01-Mode 1, 16 bit count mode
10-Mode 2, Auto reload mode
11-Mode 3, Split Timer mode

TCON
7 6 5 4 3 2 1 0
TF1 TR1 TF0 TR0
  • TRx: Timer x run control

0 = Timer not running
1 = Timer running

  • TFx: Timer x OverFlow flag

0 = Timer has not overflowed/rolled over
1 = Timer has overflowed/rolled over




Timer Calculation

8051 Oscillator frequency is divided by 12 and then fed to the controller, Time to increment the Timer count by one(timer tick) can be determined as below.
tick = (1/(Fosc/12)
$$tick = 12/Fosc$$ For Fosc == 11.0592Mhz, the tick time will be
tick = 12/11.0592M = 1.085069444us = 1.085us

Now the Timer value for the required delay can be calculated as below.
Delay = TimerCount * tick
Count = (Delay/tick)
RegValue = TimerMax- Count
RegValue = TimerMax-(Delay/tick) = TimerMax - (Delay/1.085us)
$$RegValue = TimerMax-((Delay/1.085) * 10^6)$$

Timer Mode1

The timer in Mode-1 can be used as a 16-bit timer to count from 0000 to FFFFH thus allowing to generate a wide range of delay. The timer value for the required delay needs to be loaded into Timer Count registers TH & TL. After loading the values to the register, the timers must be started. Now the Timer starts counting up and once it reaches the max value(0xffff), it rolls back to zero setting the overflow flag. At this point, the timer values must be reloaded and the overflow flag should also be cleared.

Timer Calculation for 50ms delay

Fosc = 11.0592Mhz
Delay = 50ms
$$RegValue = TimerMax-((Delay/1.085) * 10^6)$$ RegValue = 65536 - (50ms/1.085)*10^6 = 65536 - 46082 = 19453 = 0x4BFD

Polling Method

Interrupt Method


Timer Mode2

fig 4:Mode 2

The timer in Mode-2 can be used as an 8-bit timer to count from 00 to FFH . The timer value for the required delay needs to be loaded into Timer Count registers TH(which is copied to TL). After loading the values to the register, the timers must be started. Now the Timer starts incrementing TL and once it reaches the max value(0xff), it rolls back to zero setting the overflow flag and reloads the value from TH.

Timer Calculation for 250µs delay

Fosc = 11.0592Mhz
Delay = 250µs
$$RegValue = TimerMax-((Delay/1.085) * 10^6)$$ RegValue = 256 - (250µs/1.085)*10^6 = 256 - 230 = 26 = 0x1A

Interrupt Method



00 Lpc1768 Timer.jpg

Would like to have your feedback and suggestions here;